Beschreibung
The push-in thermocouple may be used in connection with the standart DIN EN 14597 (DIN 3440), approved temperature control and limiter device, in heat transfer systems according to DIN 4754. With the Seebeck effect it can beused for temperature measurment in the operating medium air. The thermocouple is particularly suitable for applications in heating, furnace and apparatus construction. This double thermocouple 2 x NiCr-Ni DIN EN 60584 (class 2) is made for temperatures from -35 to +800°C. The terminal head in form B (M24 x 1,5) is made of aluminium die-cast and can withstand ambient temperatures up to 100°C. The 15 mm thick protection tube is made of stainless steel 1.4571 and is stepped at the tip 40 mm to diameter 5,5 mm. The stainless steel protects the measuring insert against chemical influences and mechanical damage. The installation length can be variably selected between 50 and 460 mm by sliding stop flange. The thermocouple is intended exclusively for temperature measurments in gaseous media (air).
Merkmale
| Verpackungseinheit | 1 |
| Gewicht | 0,85 |
| Gewichtseinheit | KG |
| Gewichtbezugsmenge | 1 |
| Länge | 50 cm |
| Geeignet für sonstige Anwendungsbereiche | ja |
| Mit Sackrohr | ja |
| Klasse Sensor | Klasse 2 |
| Kurzbeschreibung | Thermocouple, DIN EN 14597, 2 x NiCr-Ni, 15 x 500 mm, flange, -35 to +800°C |
| eClass 11.0 - Klasse | 27200491 |
| UNSPSC 14.0801 - Klasse | 40101800 |